Slc 500 modular hardware style user manual rockwell automation. Alternatively, you can buy a newused slc503 5 04 or 5 05 to avoid of headache of trying to communicate with the 5 02. Also you will need some kind of device to hook up over the 485 port. Allen bradley rslogix 500 plc programming ab plc software.
Windows programming software rslogix 500 programming software maximizes. Additionally, this processor has 4,000 instructions of user memory. The io configuration must be specified before downloading the initial project and going online. The proprietary data network used by allen bradley plcs to communicate information to and from other plcs on the.
Local chassisslots 330 330 programming software rslogix 500, plc 500 a. View online or download allen bradley slc 502 installation instructions manual. For see page important user information 4 safety considerations 5 install 6 apply power to. The problem is when i tried to communicate with the plc with a pic 1747 and rslinx 2. Buy 1747pic ab slc501, 5 02, 5 03 series plc programming cable rs232 to rs485. Specification slc 501 1747l511, l514 slc 502 1747l524 program memory 1k or 4k instructions 4k instructions additional data storage 0 0 maximum io capacity 3940 discrete inputs 3940 discrete. The 502 and 503 platforms had dh485 data highway communications. Slc 502 processors let you configure modular controllers of up to 4096. Over time, you can then retrofit other parts of the system eg. Usb cables free delivery possible on eligible purchases. In general, the slc500 programming software has a few less features than the plc5 programming software. You can get a cheaper 485232 converter designed to work with the slc family. Jan 20, 2011 configuring the ip address for an slc 5 05 controller can be accomplished in one of two ways, with a serial cable or the bootp server configuration utility in rslinx software version 2. All parts new or reconditioned are covered by aotewell 12 month warranty.
Specifically, the slc 5 03, slc 5 04, and slc 5 05 all have a 9 pin dshell serial port. You should only need the new slc 5 05 and a spare io rack. Communicate and download over dh485 using rslinx and rslogix 500. Our slc 501, 502 and 503 8k series controllers are discontinued and no longer available for sale. Pyramid integrator plc5250 in most cases, as much of the original io racksmodules, field wiring, communication networks, and. Select driver from available driver types and press add new button note.
In addition to the features of the slc 502, they have a second builtin. Specifically, the slc503, slc502, 501, fixed slc500 all have an rj45 dh485 port. Problems communicating with slc 500 501 allen bradley. Next, insure you have the rslogix 500 programming software and either the 1747cp3 or equivalent null modem cable. This slc 502 processor has 4096 inputs, 4096 outputs, and 480 analog io. Apr 26, 2015 rslogix 500 to edit, upload and executing a ladder logic program using a micrologix 1500 plc duration. Page 10 slc 501 and slc 502 modular processors communication receive receive or initiate dh485 slc 501 slc 502 1 a 1747pic is required when connecting to the dh485 channel for. The first slc, known simply as an slc500, was an integrated platform containing the cpu, power supply, and io all in one package. A total of 2 cables are required, 1747uic, plug into. Slc 500 controllers allenbradley rockwell automation.
Manufactured by rockwell automation, the slc 5 02 is a slightly less powerful model than the slc 5 03 and is intended for less intensive operations. Selecting a memory module for the slc 501 and slc 502. Rslogix 500 to edit, upload and executing a ladder logic program using a micrologix 1500 plc duration. Motion analyzer software is a comprehensive motionapplication sizing tool used for analysis, optimization, selection and validation of your kinetix motion control system. How to configure the 1747pic to connect to a slc 500, slc 501, or slc 502 setting up a pic driver for allen bradley plcs this is used for slc 500, slc 501, slc 502, you will need a 1747pic cable or equivalent.
In the plant most of the plcs are simatic s7 300 and 400 and a few are rockwell plcs. Dear all,we are executing a project to aquire plant data through network. Manufactured by rockwell automation, the slc 502 is a slightly less powerful model than the slc 503 and is intended. This ab software and hardware may control 5vdc, 24vdc, or 120vac circuits, high. Slc 503, slc 504, and slc 505 modular processors 11 publication 1747in009benp march 2008 3. The driver uses the csp protocol, sometimes refered to as abethernet. Reproduction of the contents of this manual, in whole or in part, without written permission of rockwell automation, inc. We are aquiring all the data on a central wincc server through ethernet from all the plcs. Plc programming with rslogix 500 engineer and technician. To connect it to a pcs serial port you need an allenbradley 1747pic unit. Allenbradley 1747l524 is a slc 500 slc 502 processor. Plc cable for programming slc 500, 501, 502, and 503 plcs. Advanced interface programming software for the slc500, called plc500 a.
Then take your new slc 505 and place it in a second io rack, a spare one on your desk somewhere. Allen bradley 93012se2200 rsview 32 works 300 plc software rev 6. Kepserverex is more than an opc serverits a connectivity platform for industrial automation and iot. Next, insure you have the rslogix 500 programming software, for which there is. One of the most popular series of plcs from the 1990s to mid2000s is the allenbradly slc 500 series.
Slc 5 01, slc 5 02, slc 5 03, slc 5 04, and slc 5 05. Slc 500 modular hardware style catalog numbers 1747l511, 1747l514, 1747l524, 1747l531, 1747l532, 1747l533, 1747l541, 1747l542, 1747l543. Pyramid integrator plc 5 250 in most cases, as much of the original io racksmodules, field wiring, communication networks, and hmiscada as you want can be left intact. Slc 501 and slc 502 modular processors catalog numbers 1747l511, 1747l514, and 1747l524 inside. This project uses slc 502 plc for communication, the method is for reference only. Opc certification requires extensive testing to ensure true interoperability. Open rslinx by selecting start programs rockwell software rslinx rslinx. Buy 1747pic ab slc501, 502, 503 series plc programming cable rs232 to rs485. Like most good things, even the plc5 has come to an end. Mostly allen bradley plc use two softwares for plc programming. Slc 501, 502 or 503 processor with a 1747aic isolated link coupler. But dont worry while the plc5 control system is discontinued and no longer available for sale, we have the tools and.
On site there is a slc 5 02 plc 1996, with spare slots. Allenbradley 1747l524 slc 5 02 processor 4k memory dh485 communication. Panelmate and plc except the plc that you want to load. Before you begin, first insure your slc500 has serial port not all do. Slc 5 01 and slc 5 02 modular processors catalog numbers 1747l511, 1747l514, and 1747l524 inside. While the 501 could communicate over a dh485 network. But dont worry while the plc5 control system is discontinued and no longer available for sale, we have the tools and assistance to help you migrate to our controllogix control systems. Rslogix 500 downloading a new project to a controller slc 505. While the 501 could communicate over a dh485 network, it was only able to respond to messages sent it from either a pc or future slc500 controllers 502, 503, etc. Feb 01, 2008 i need to make program changes to a slc 502. The allenbradley 1747l524 is a slc 500 slc 502 processor. Communicate and download over data highway plus using rslinx and rslogix article. Will rslinx auto config the port and then autodetect the processor.
Then take your new slc 5 05 and place it in a second io rack, a spare one on your desk somewhere. Btw, dont confuse the plc 515, 520, 540, etc with the slc 502, 503. Insert a new battery into the battery retaining clips. Panelmate and plc except the plc that you want to load the program. Give information about dh, control net, devicenet and ethernet protocol. Slc 504 programmable controllers automation networks. To support your transition, we recommend that you migrate to our. With most modern plcs, all you need to start programming or. Allen bradley plc interview questions and answers ab plc. Slc 502 for more complex applications, communications, faster scan times, and.
The bootp utility is the less common of the two methods, but it is a convenient tool if the serial port or serial cable is not available. How to configure the 1747pic to connect to a slc 500, slc. To support your transition, we recommend that you migrate to our compactlogix 5380 control platform. However, i cant agree with you, because at this jobsite, there is a third slc 501 and i have succesfully connected, uploaded, and downloaded software to that slc 501 using this.
Plug the battery connector into the socket as shown above. The pannel view needs its own software also to program it. Hi, i have been asked to modify a machine as follows. How to configure the 1747pic to connect to a slc 500, slc 5. On site there is a slc 502 plc 1996, with spare slots. How to connect to an allenbradley slc 500 plc plc one. To access the slc 5 02 you will need the rockwell programing software rslogix 500, and rslinx to comunicate with it. The slc 501, 5 02, and 503 use dh485 via their rs485 8pin rj45 jack. Identifying slc 5 02 processor communication errors. The allenbradley 1747l524 slc 5 02 is a popular modular processor. Based on midsized plc processors, the advanced programming sets of the slc 5 02 give it an edge over its market.
Learn how to setup rslinx dh485 communications to an ab slc500 and then download using rslogix in episode 17 of the automation minute season 3. Rslogix 500 downloading a new project to a controller slc 5. Jan 27, 2017 learn how to setup rslinx dh485 communications to an ab slc 500 and then download using rslogix in episode 17 of the automation minute season 3. Configuring the ip address for an slc 505 controller can be accomplished in one of two ways, with a serial cable or the bootp server configuration utility in rslinx software version 2.
For see page important user information 4 safety considerations 5 install 6 apply power to your processor 8 load your software 8 establish communications with the processor 8 troubleshoot the processor 9 specifications 10 battery handling. Configuration using rslogix 500 programming software. Allen bradley slc 500 plc configurator processor engnet. Specifically, the slc503, slc504, and slc505 all have a 9 pin dshell serial port. What are the differences between slc 5 series plcs.
This project uses slc 5 02 plc for communication, the method is for reference only. How to configure the 1747pic to connect to a slc 500, slc 501, or slc 502 setting up a pic driver for allen bradley plcs this is used for slc 500, slc 501, slc 502, you will need a 1747pic cable or. Youll need a 1747uic the ebay knockoff adaptors work just fine. Each slc 501 processor has a dh485 port for programming and. Power it up and download the modified program from the slc 5 02. Plc programming with rslogix 500 will get you up to speed fast.
Communicate and download over data highway plus using rslinx and. Then when ready, power down the slc 5 02, swap the slc 5 02 with the new slc 5 05, and turn the power back on. The next slc500 controller to come out was the slc502. With a large number of legacy systems, the original programming cables and software are often long lost by the time you want to make updates or need to troubleshoot an issue. Allen bradley 1747l524 module cpu processor slc 500 series c b216888 product details. Rockwell automation has announced that some slc 500 bulletin. This software facilitates the machine design process, letting you quickly design and validate new machine concepts without purchasing or installing physical equipment. Specification slc 501 1747l511, l514 slc 502 1747l524 program memory 1k or 4k instructions 4k instructions additional data storage 0 0 maximum io capacity 3940 discrete inputs 3940 discrete outputs 4096 discrete inputs 4096 discrete outputs max. How to connect to an allenbradley slc 500 plc dmc, inc. They both came with a dh485 programming port that accepted an rj45 style connector.
Allen bradley plc connection procedure columbia machine. Why the allenbradley ab 1747pic always had trouble working in microsoft windows software. Power it up and download the modified program from the slc 502. Allenbradley slc 501 installation instructions manual pdf. Local chassisslots 330 330 programming software rslogix 500, plc500 a. It can also be used for most allen bradley products configured for dh485 including the slc 504, 505, controllogix, micrologix. Specification slc 5 01 1747l511, l514 slc 5 02 1747l524 program memory 1k or 4k instructions 4k instructions additional data storage 0 0 maximum io capacity 3940 discrete inputs 3940 discrete outputs 4096 discrete inputs 4096 discrete outputs max. The allenbradley 1747l524 slc 502 is a popular modular processor.